·Testing sample varieties: hot rolling, cold rolling
silicon steel materials, permalloy, amorphous and nm
crystal.
·Testing sample shapes: ribbon and chip open samples,
annular, E and U closing samples.
·Open circuit samples adopt epstein trames to form closed
magnetic circuit, can also select permeameter. Closing sample
can be put under direct winding measurement, finished
transformer can be also put under direct measurement.
·Sample( iron core), magnetizing coil (N1) and measuring
coil (N2) form a no-load transformer.
·On-inductive resistance connected on magnetizing coil loop
to determine magnetizing current and magnetic field intensity
through the measurement of pressure drop on non inductive
resistance, magnetic field peak value can be locked through
digital feedback, magnetic field lock precision 0.5%.
·Magnetic induction density obtained through digital
integration of coil measuring voltage, magnetic induction peak
value locked through digital feedback, magnetic induction lock
precision 0.2%.
·Power source and sampling amplifier integrated into a
casing with simple interface: one RS232 interface connected to
the computer, two way voltage signal connected to A/D
card.
·Adopt volammetry and digital integration to measure
dynamic hysteresis loop, can accurately measure dynamic
magnetic characteristic parameters such as μa, δ, Ps, Br and
Hc, etc.
·Automatic and continuous measurement up to 255 testing
points, the testing time of every testing point is about 30
seconds, fixed-frequency, fixed Bm or fixed Hm optional in
multipoint test.
|